4. | Make these input tests at the connector.
- If any test indicates a problem, find and correct the cause, then recheck the system.
- If all the input tests prove OK, the alarm control siren must be faulty, replace it.
Cavity | Wire | Test condition | Test: Desired result | Possible cause if result is not obtained |
---|
1 | BLK | Under all conditions | Check for continuity to ground: There should be continuity. | - Poor ground (G652)
- An open in the wire
| 2 | GRN | Under all conditions | Check for continuity between the No. 2 terminal and No. 2 terminal of the ultrasonic sensor: There should be continuity. | An open in the wire | 3 | YEL | Under all conditions | Check for continuity between the No. 3 terminal and T15 terminal of the MICU: There should be continuity. | An open in the wire | 4 | WHT | Under all conditions | Check for voltage to ground: There should be battery voltage. | - Blown No. 16 (15 A) fuse in the under-hood fuse/relay box
- An open in the wire
|
|